Electrical & fluid power diagram symbols pack

Line symbols for wiring and single-line diagrams, ladder logic and lighting layouts, and for hydraulic and pneumatic circuits: directional valves, cylinders, pumps, pressure and flow valves and air preparation.

411 symbols · Schematic 411

  • 411 symbols as editable SVG and PNG
  • Ready to import as an image
  • One ZIP with everything, or one by one
  • They use no downloads and open in the Symbol Builder

Every symbol in the pack 411

Previews carry a watermark; the files you download do not.

Electrical diagrams 261Open the category →

Breakers, fuses & switchgear 22Schematic 22

Thermal-magnetic circuit breaker Disconnector (isolator) Fuse Fuse-disconnector Residual current device (RCD) Thermal overload relay (electrical diagram symbol) Surge arrester Draw-out circuit breaker Power circuit breaker (square) Bus coupler (tie breaker) Busbar with feeders Busbar (horizontal) Busbar (vertical) MV switchgear cell MV contactor Disconnector (horizontal) Earthing switch Enclosure / equipment boundary MV fuse (with striker) Load-break switch Spark gap Switch-disconnector

Transformers, motors & generators 20Schematic 20

Autotransformer Generator Single-phase motor Three-phase motor DC motor Two-winding transformer Current transformer (CT) Two-core current transformer Synchronous generator Squirrel-cage induction motor Slip-ring induction motor Synchronous motor Neutral grounding reactor Neutral grounding resistor Reactor (choke coil) Three-winding transformer Two-winding transformer Dyn11 Wye-wye transformer YNyn0 Zig-zag earthing transformer Voltage transformer (VT)

Sources, converters & compensation 15Schematic 15

Battery / DC source Variable frequency drive (VFD) (electrical diagram symbol) Battery bank Capacitor bank (star) Variable capacitor (bank step) DC/DC converter DC/AC inverter AC/DC converter (rectifier) Harmonic filter (L-C to earth) Photovoltaic panel Generic AC source Generic DC source Grid supply (incomer) UPS (uninterruptible power supply) Wind turbine generator

Protection relays & meters 21Schematic 21

Ammeter Energy meter Voltmeter Power quality analyzer Ampere-hour meter Power factor meter Frequency meter Varmeter Wattmeter Protection relay 21 (distance) Protection relay 25 (synchro-check) Protection relay 27/59 (under/overvoltage) Protection relay 32 (reverse power) Protection relay 46 (negative sequence) Protection relay 49 (thermal overload) Protection relay 50/51 (instantaneous/time overcurrent) Protection relay 50N/51N (ground overcurrent) Protection relay 67 (directional overcurrent) Protection relay 81 (frequency) Protection relay 86 (lockout) Protection relay 87 (differential)

Contacts, coils & control devices 29Schematic 29

Buzzer (electrical diagram symbol) Contactor coil Relay coil Changeover contact NC contact NO contact Off-delay timed contact On-delay timed contact Horn (acoustic signal) Indicator lamp NC limit switch NO limit switch PLC digital input PLC digital output Emergency stop pushbutton (electrical diagram symbol) NC pushbutton NO pushbutton Two-position selector switch Three-position selector switch Solenoid valve (coil) Flow switch contact Level switch contact Pressure switch contact Thermostat contact PLC analog input module (2 ch) PLC analog output module (2 ch) PLC digital input module (4 ch + COM) PLC digital output module (4 ch + COM) Safety relay with terminals

Electronic components 14Schematic 14

Bridge rectifier Capacitor Polarized capacitor Diode Inductor / coil LED (light emitting diode) Potentiometer Resistor Variable resistor Thyristor (SCR) NPN transistor PNP transistor Triac Zener diode

Conductors, earthing & connections 27Schematic 27

Antenna Conductor (wire) Crossing without connection Protective earth Frame / chassis Earth (ground) Crossing with connection PE terminal Terminal Cable termination (sealing end) Cable joint (splice) Underground cable Three-conductor line Line 3P + N + PE Neutral conductor (N) Protective conductor (PE) PEN conductor Earth rod (electrode) Earth grid (mesh) Noiseless (clean) earth Neutral earthing (service earth) Overhead line Link line (from elsewhere) Link line (continues elsewhere) Load (generic) Star point with neutral Point of common coupling (PCC)

Ladder diagram symbols 46Schematic 46

Interlocked rungs (two contactors) Ladder power rails L1/L2 Start-stop rung with seal-in Circuit breaker CB (NEMA) Three-pole circuit breaker (NEMA) Control relay coil (CR) Motor starter coil (M) NC contact (NEMA) NO contact (NEMA) Control transformer Counter (CTU) Control relay CR with contacts Emergency stop mushroom (NEMA) Flow switch NC Flow switch NO Fuse (NEMA) Alarm horn (NEMA) Level switch NC Level switch NO Limit switch NC Limit switch NC, held open Limit switch NO Limit switch NO, held closed Direct-on-line motor starter (power) Overload contact NC (OL) Overload heater element (OL) Pushbutton NC (NEMA) Pushbutton NO (NEMA) Pilot light amber (A) Pilot light blue (B) Pilot light green (G) Pilot light red (R) Pilot light white (W) Pressure switch NC Pressure switch NO 2-position selector switch (NEMA) 3-position selector switch (NEMA) Start/stop pushbutton station Temperature switch NC Temperature switch NO Timer coil, off-delay Timer coil, on-delay Off-delay contact NC (NEMA) Off-delay contact NO (NEMA) On-delay contact NC (NEMA) On-delay contact NO (NEMA)

Lighting on floor plans 19Schematic 19

Beacon light (flashing) Rotating beacon (plant layout symbol) Surface ceiling luminaire Recessed downlight (plant layout symbol) Emergency luminaire Illuminated exit sign (plant layout symbol) Explosion-proof luminaire (Ex) Floodlight (plant layout symbol) Fluorescent luminaire (single tube) Fluorescent luminaire with emergency pack Fluorescent luminaire (twin tube) Industrial high-bay luminaire Linear LED luminaire Recessed panel luminaire (suspended ceiling) Adjustable spotlight Lighting pole (single arm) Lighting pole (double arm) Wall-mounted luminaire (bracket) Watertight luminaire (IP65)

Switches & sockets on floor plans 23Schematic 23

Single-phase socket outlet Double socket outlet Three-phase socket outlet (3-pole) Three-phase socket outlet with neutral and earth (5-pole) CEE industrial socket 3P+E 16 A CEE industrial socket 3P+N+E 32 A CEE industrial socket 3P+N+E 63 A Data outlet (RJ45) Floor socket box Weatherproof socket outlet (IP44) Earthed socket outlet (Schuko type) Telephone outlet Two-way switch (plan) Dimmer switch Double-pole switch (plan) Intermediate (cross) switch (plan) Photocell / twilight switch Ceiling presence detector (PIR) Wall presence detector (PIR) Pull-cord switch Push button (bell push) (plan) Single-pole switch (plan) Timer switch (plan)

Lamps, pushbuttons & sounders on plans 25Schematic 25

Pilot lamp blue (B) Flashing pilot lamp red (R) Flashing pilot lamp yellow (Y) Pilot lamp green (G) Pilot lamp red (R) Pilot lamp white (W) Pilot lamp yellow (Y) Pushbutton blue blue (NO) (B) Double pushbutton start/stop (I/O) Pushbutton green start (NO) (G) Illuminated pushbutton green (G) Illuminated pushbutton red (R) Illuminated pushbutton yellow (Y) Pushbutton red stop (NC) (R) Pushbutton white white (NO) (W) Pushbutton yellow yellow (NO) (Y) Electric bell Signal tower, 1 level (red) Signal tower, 2 levels (R-G) Signal tower R-Y-G with buzzer Signal tower, 3 levels (R-Y-G) Signal tower, 4 levels (R-Y-G-B) Signal tower, 5 levels (R-Y-G-B-W) Combined sounder-beacon (horn + lamp) Siren

Hydraulics & pneumatics diagrams 150Open the category →

Directional valves: 2/2 and 3/2 20Schematic 20

2/2 valve, normally closed, lever with detent 2/2 valve, normally closed, pneumatic pilot, spring return 2/2 valve, normally closed, push button, spring return 2/2 valve, normally closed, solenoid, spring return 2/2 valve, normally open, push button, spring return 2/2 valve, normally open, solenoid, spring return Proportional 2/2 valve (continuous flow control) 3/2 valve, normally closed, hydraulic pilot, spring return 3/2 valve, normally closed, lever with detent 3/2 valve, normally closed, foot pedal, spring return 3/2 valve, normally closed, pneumatic pilot, spring return 3/2 valve, normally closed, plunger, spring return 3/2 valve, normally closed, push button, spring return 3/2 valve, normally closed, idle-return roller, spring return 3/2 valve, normally closed, roller, spring return 3/2 valve, normally closed, solenoid, spring return 3/2 valve, normally closed, solenoid with pilot stage, spring return 3/2 valve, normally open, pneumatic pilot, spring return 3/2 valve, normally open, push button, spring return 3/2 valve, normally open, solenoid, spring return

Directional valves: 4 and 5 ports 30Schematic 30

3/3 valve, closed centre, double solenoid, spring centred 4/2 valve, double hydraulic pilot (bistable) 4/2 valve, double solenoid (bistable) 4/2 valve, hydraulic pilot, spring return 4/2 valve, lever with detent 4/2 valve, pneumatic pilot, spring return 4/2 valve, solenoid, spring return 4/2 valve, solenoid with pilot stage, spring return 4/3 valve, closed centre, double pilot, spring centred 4/3 valve, closed centre, double solenoid, spring centred 4/3 valve, float centre (A-B-T), double solenoid, spring centred 4/3 valve, open centre, double solenoid, spring centred Proportional directional valve 4/3, closed centre, double solenoid Servo valve 4/3 (torque motor and hydraulic pilot) 4/3 valve, tandem centre (P to T), double solenoid, spring centred 5/2 valve, double pneumatic pilot (bistable) 5/2 valve, double solenoid (bistable) 5/2 valve, double solenoid with pilot stage (bistable) 5/2 valve, hydraulic pilot, spring return 5/2 valve, lever with detent 5/2 valve, foot pedal, spring return 5/2 valve, pneumatic pilot, spring return 5/2 valve, push button, spring return 5/2 valve, roller, spring return 5/2 valve, solenoid, spring return 5/2 valve, solenoid with pilot stage, spring return 5/3 valve, closed centre, double solenoid, spring centred 5/3 valve, exhaust centre, double solenoid, spring centred 5/3 valve, pressure centre, double solenoid, spring centred Proportional directional valve 5/3, closed centre, double solenoid

Pressure control valves 10Schematic 10

Counterbalance valve with check Pressure switch (fluid power symbol) Pressure reducing valve, without relief Pressure reducing valve, with relief port Pressure relief valve Pilot-operated pressure relief valve Proportional pressure relief valve Pneumatic safety (relief) valve, exhaust to atmosphere Sequence valve Unloading valve (external pilot)

Flow, check & logic valves 12Schematic 12

Check valve (no spring) Pilot-operated check valve (pilot to open) Spring-loaded check valve (fluid power symbol) Dual-pressure valve (AND) Flow divider (two coupled motors) 2-way pressure-compensated flow control valve Quick exhaust valve Shut-off valve (manual) Shuttle valve (OR) Adjustable throttle valve One-way flow control valve (adjustable throttle with check) Fixed throttle

Cylinders 17Schematic 17

Diaphragm cylinder, single-acting Diaphragm cylinder, single-acting, spring return Double-acting cylinder Double-acting cylinder, adjustable cushioning both ends Double-acting cylinder, adjustable cushioning on cap end Double-acting cylinder, fixed cushioning both ends Double-acting cylinder, fixed cushioning on rod end Double-acting cylinder, double-ended rod Pressure intensifier (booster) Double-acting cylinder with magnetic piston and sensor Rodless cylinder (external carriage) Single-acting cylinder, return by external force Ram cylinder (plunger), single-acting Single-acting cylinder, spring return Tandem cylinder Telescopic cylinder, double-acting Telescopic cylinder, single-acting

Pumps, motors & compressors 22Schematic 22

Compressor, fixed displacement Compressor, variable displacement Electric drive motor Hydraulic motor, fixed displacement, two flow directions Hydraulic motor, variable displacement, two flow directions Hydraulic motor, fixed displacement, one flow direction Hydraulic motor, variable displacement, one flow direction Hydraulic semi-rotary actuator (limited angle) Pneumatic semi-rotary actuator (limited angle) Pneumatic motor, two directions of rotation Pneumatic motor, one direction of rotation Pneumatic motor, variable displacement Hydraulic power source (pressure) Pneumatic power source (compressed air) Hand pump (hydraulic) Hydraulic pump, fixed displacement, two flow directions Hydraulic pump, variable displacement, two flow directions Hydraulic pump, fixed displacement, one flow direction Hydraulic pump, variable displacement, one flow direction Hydraulic pump, variable displacement, pressure compensated Hydraulic pump/motor unit Vacuum pump

Tanks, accumulators & air preparation 19Schematic 19

Gas-loaded accumulator (separator) Hydraulic accumulator (general symbol) Spring-loaded accumulator Air dryer Cooler Filter (fluid power symbol) Filter with clogging indicator Filter with water separator and manual drain FRL air service unit (detailed symbol) FRL air service unit (simplified symbol) Heater Lubricator Compressed air receiver Pressurized reservoir (closed) Reservoir (simplified return symbol) Reservoir vented to atmosphere, line above fluid level Reservoir vented to atmosphere, return line below fluid level Temperature controller (heat exchanger) Water separator with manual drain

Lines, couplings & instruments 20Schematic 20

Quick coupling, connected, without check valves Quick coupling, disconnected, without check valves Quick coupling, connected, with check valves Quick coupling, disconnected, with check valves Exhaust to atmosphere, no connection Exhaust with connection (threaded) Flow meter Line crossing (not connected) Line crossing (connected) Drain or bleed line (short dashes) Flexible line (hose) Line junction (connected) Pilot line (long dashes) Working line (pressure or return) Position sensor (proximity) Pressure gauge (fluid power symbol) Silencer (muffler) Solenoid (valve coil) Pressure test point Thermometer

More about this pack

What is included
  • Clean, editable SVG. 411 symbols: 411 Schematic.
  • Ready to import. Ordinary SVG and PNG files: they import as images into your HMI editor or your drawing software.
  • One ZIP with everything. SVG with fixed colours, 512 px PNG with a transparent background, and a CSV index with the names in English and Spanish, sorted by family.
  • No downloads used, and editable. Pack symbols do not count against monthly downloads, on the free account either, and they open in the Symbol Builder so you can modify them.
Which HMI it works with

They are ordinary SVG and PNG files. They import as images into any HMI or SCADA editor that accepts images; if yours does not take SVG, use the PNG. They do not depend on any vendor or proprietary format.

What happens after you pay
  1. You pay on Stripe. Stripe takes the payment with the account you are signed in with here. You get their receipt by email.
  2. You come back to this page. The pack is linked to your account within seconds. There is nothing to do and no code to enter.
  3. Download and edit. Get everything as a ZIP from this page, or open any pack symbol in the library: download it without using your downloads, or open it in the Symbol Builder.
Pack or plan

For comparison: the Starter plan is 19.99 € a month and includes 50 downloads a month of any symbol in the library. The pack is 411 symbols for one kind of equipment that you pay for once.

Licence

You may use the pack symbols in your own projects and in your clients’ projects, commercial ones included. You may not resell or redistribute the files, on their own or inside another library. Terms of service.

Schematic symbols are drawn from scratch following the usual conventions. They are not certified against any standard: check them against your company standard before issuing documentation.