Alarms & status indicators
Alarm priority shapes P1 to P4, bells and banners, signal quality, operating modes, interlocks and bypasses, flow arrows and communication status.
All 152 Alarm priority symbols & bells 20 Alarm states 8 Alarm banners & counters 15 Signal quality 16 Operating modes 13 Interlocks, permissives & locks 16 Communication status 10 Notifications 9 Batch & recipe states 12 Flow direction 21 Display hierarchy levels 12
152 of 152 symbols
Clear filters
Alarm priority symbols & bells 20
Alarm bell P1 critical ISA-101 +3
Alarm bell with horn silenced (alarm still active) ISA-101
Alarm P1 critical (round numbered badge) ISA-101 +2
Alarm P1 critical (triangle, unacknowledged) ISA-101 +2
Alarm P2 high (diamond, unacknowledged) ISA-101 +2
Alarm P3 medium (circle, unacknowledged) ISA-101 +2
Alarm P4 low / advisory (square, unacknowledged) ISA-101 +2
Alarm states 8
Alarm shelved (temporarily blocked) ISA-101
Alarm in service (enabled) ISA-101
Alarm out of service (maintenance) ISA-101
Active unacknowledged alarm (ringing bell) ISA-101
Alarm in normal state (no alarm) ISA-101
Active acknowledged alarm ISA-101
Alarm returned to normal, awaiting acknowledgement ISA-101
Alarm suppressed by design ISA-101
Alarm banners & counters 15
Unacknowledged alarm counter (bell) ISA-101
Alarm summary banner with active P1 highlighted ISA-101 +1
Alarm summary 2x2 grid ISA-101
Alarm summary banner by priority (P1-P4) ISA-101
Alarm summary column ISA-101
Shelved and suppressed alarm counters ISA-101
Alarm summary banner, no active alarms ISA-101
Total active alarm counter (bell) ISA-101
Last alarm line P1 ISA-101 +1
Alarm counter P1 (triangle) ISA-101 +3
Signal quality 16
Signal quality: stale (not refreshed) ISA-101
Signal quality: good ISA-101
Signal quality: forced / overridden ISA-101
Signal quality: out of range (high) ISA-101
Signal quality: out of range (low) ISA-101
Signal quality: uncertain ISA-101
Signal quality: bad ISA-101
Signal quality: simulated ISA-101
Signal quality: no communication ISA-101
Process value: stale (not refreshed) ISA-101
Process value: good quality ISA-101
Process value: forced ISA-101
Process value: uncertain quality ISA-101
Process value: bad quality ISA-101
Process value: simulated ISA-101
Process value: no communication ISA-101
Operating modes 13
Automatic mode ISA-101
Cascade mode ISA-101
Remote setpoint mode ISA-101
Local (at the field) mode ISA-101
Maintenance mode ISA-101
Manual mode ISA-101
Ratio mode ISA-101
Remote (control room) mode ISA-101
Hand-Off-Auto selector in Off ISA-101 +2
Local-Remote selector in Local ISA-101 +1
Interlocks, permissives & locks 16
Start inhibited ISA-101
Lockout/tagout (LOTO) ISA-101
Bypass active (equipment or signal bypassed) ISA-101
Timed bypass active ISA-101
Padlock closed (locked) ISA-101 +2
Safety function bypassed ISA-101
Safety function tripped ISA-101
Safety function healthy ISA-101
Interlock active (blocking the action) ISA-101
Interlock tripped (broken chain) ISA-101
Interlock healthy (conditions met) ISA-101
Permissive not met (start not allowed) ISA-101
Permissives met (ready to start) ISA-101
Reset required (manual re-arm) ISA-101
Communication status 10
Degraded communication (packet loss) ISA-101
Communication error (broken link) ISA-101
Heartbeat (watchdog) OK ISA-101
Heartbeat (watchdog) lost ISA-101
Communication OK ISA-101
Reconnecting ISA-101
Redundant network: link A down ISA-101
Redundant network: both links OK ISA-101
Link disabled or not configured ISA-101
Communication timeout ISA-101
Notifications 9
Warning message ISA-101
System error message ISA-101
Information message ISA-101
New unread message ISA-101
Success message ISA-101
Operator message ISA-101
Message requiring operator response ISA-101
Event log ISA-101
System event ISA-101
Batch & recipe states 12
Batch aborted ISA-101
Batch aborting (transition) ISA-101
Batch complete ISA-101
Batch idle ISA-101
Batch running / start ISA-101
Batch stopped ISA-101
Batch stopping (transition) ISA-101
Advance to next sequence step ISA-101
Batch paused ISA-101
Batch restarting ISA-101
Recipe loaded ISA-101
Recipe modified, unsaved ISA-101
Flow direction 21
Bidirectional flow arrow horizontal ISA-101 +1
Elbow flow arrow: right then down ISA-101 +3
Flow arrow right ISA-101 +3
Flow stopped (no flow) ISA-101
Flow arrow diagonal down-right ISA-101 +3
Forward direction (FWD) ISA-101 +1
Clockwise rotation ISA-101 +1
Recirculation (return loop) ISA-101
Unwanted reverse flow (backflow) ISA-101
Display hierarchy levels 12
Display level 1 indicator (overview), grid ISA-101 +3
Display level 1 indicator (overview), bars ISA-101 +3
Display level 1 indicator (overview), pyramid ISA-101 +3
No symbols match these filters Try another type or state, or clear the filters to see the whole category.Clear filters
ISA-101 flat symbols use grey for the equipment and keep colour for state only (green running, grey stopped, red fault, orange P2, yellow no feedback, blue manual). Each state is a separate file, ready to map to a multi-state object.
Browse and preview for free. Downloading the editable SVG needs an account and counts against your plan’s monthly downloads. Once downloaded, use it in your own HMI, SCADA and documentation projects, commercial ones included. Do not resell or redistribute the symbols as a library or pack.